控制器ANKO-V1.8
1、 控制器部分
1. Controller
a、液晶图文显示,对燃烧机的各项参数实时显示,主要为开机画面、运行时间、点火次数、环境温度、运行状态(分为待机、小火、大火)故障提示等。
a. LCD graphic and text display - real-time display of combustor parameters, mainly including startup screen, running time, ignition times, ambient temperature, running status (standby, small flame and large flame), and fault indication, etc.
b、内部为双ECU,主控和显示器独立工作,
运行速度更高。反应时间更快。
b. Internal double ECUs, master control and monitor in autonomous working, with faster running speed and quicker response time.
c、点火失败后三次自重启功能。
c. Function of auto restart for three times after ignition failure.
d、 内部PCB电路板保护措施齐全,保证电
磁阀端因意外短路后不会烧毁主板,一分钟内即
可维修好重新运行。
d. Internal PCB circuit board with complete protection, preventing the solenoid valve side from burning the motherboard after accidental short-circuit, and ensuring repair and re-running within one minute.
e、点火电压~15kv。主板内部 有防高压线脱落后外部意外打火功能。
e. Ignition voltage ~15kv. Anti-HV line is provided in the motherboard that can trip to prevent external ignition by accident.
f、设有USB端口,可对不同客户的特殊要求定制升级。
f. USB port can be customized and upgraded according to the particular requirements of different customers.
g、火焰探测为UV电离探测,无需专用探测地线,只需把燃烧机与大地可靠连接。
g. Flame detection in the way of UV ionization, which is realized simply by reliable connection between the combustor and the earth, without the need for specialized detection earthing.
h、主板内部设有应急测试按钮当控制柜因意
外无输出信号时,按下应急按钮燃烧机则始终处于小火运行状态,不至于炉温掉的太快,此状态仍然享有火焰检测保护。注意正常工作时此按钮必须复位。
h. Emergency test button is provided in the motherboard, which can be pressed in case of output signal failure from
the control cabinet, to keep the combustor in the running status of small flame, preventing quick dropping of furnace temperature, while still enjoying flame detection protection. Note that this button must be reset during normal working.
i、 工作电压: AC220V 50HZ
j、额定功率: 12W
k、触点输出能力: 2A
l 、工作温度范围: -10℃—85℃
i. Working voltage: AC220V 50HZ
j. Rated power: 12W
k. Contact output capacity: 2A
l. Working temperature range: -10℃—85℃